SICK MLP1-SMMA0AC (1077943) Safety Locking Device, Transponder, Power to Lock, 500 N Force, 45mm Safe Switch Distance
Sensor principle Transponder Locking principle Power to lock Locking force 500 N Retaining force 25 N Offset tolerance ≤ 5 mm Safe switch off distance Sar 45 mm For process protection only ✔ Safety integrity level SIL3 (IEC 61508), SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) 1) PFHD (mean probability of a dangerous failure per hour) 1.5 x 10-8 (EN ISO 13849) 2) TM (mission time) 20 years (EN ISO 13849) Type Type 4 (EN ISO 14119) Actuator coding level Low coding level (EN ISO 14119) Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state.